У зв'язку зі святкуванням Нового Року ми працюємо за наступним графіком: • з 31.12.24(Вт) по 02.01.25(Чт) не працюємо • з 03.01.25(Пт) працюємо в звичайному режимі.
Інтерет-магазин приймає замовлення цілодобово 24/7 !
Web Speech API is not supported by this browser. Install Google Chrome.
Voice input also works in Safari, Yandex, as well as mobile browsers Huawei, Opera and Samsung..
UT120A pocket digital multimeter with automatic range selection is designed to measure AC and DC voltage, resistance, voltage drop across the p-n junction and continuity. The display is liquid crystal (LCD) 4-digit. Has an automatic power off function.
The device is supplied in a case for carrying and storage, in which the probes (non-removable) are also placed.
The dimensions of the case are 90x120x18 mm.
Weight 100 grams.
Features:
Function
Range
Resolution
Accuracy±(a%+b)
Input protection
Description
DCV
4V
1mV
±(0.8%+1)
600V AC
40V
10mV
400V
100mV
600V
1V
±(1%+3)
ACV
4V
1mV
±(1.2%+3)
600V AC
Input impedance ≥10MΩ
Frequency response: 40∽400Hz
Display: Sine wave effective value (average value response)
40V
10mV
400V
100mV
600V
1V
±(1.5%+5)
Resistance (Ω)
400Ω
0.1Ω
±(1.2%+2)
600V AC
Open circuit voltage about 0.45V
4kΩ
1Ω
±(1%+2)
40kΩ
10Ω
400kΩ
100Ω
4MΩ
1kΩ
±(1.2%+2)
40MΩ
10kΩ
±(1.5%+2)
Frequency (f)
99.99Hz
0.1Hz
±(0.5%+3)
600V AC
In the AC/DC slot, press HZ/% button turn into Hz to measure
Accuracy :inputsine wave voltage 10Hz∽10kHz:≥1Vrms
10kHz∽100kHz:≥30Vrms
999.9Hz
1Hz
9.999kHz
0.01kHz
10MHz
0.1kHZ
Duty
0.1%-99.9%
0.10%
600V AC
In the AC/DC slot Press HZ/% button turn into DUTY to measure (Reading is for reference only)
Diode
1mV
0.5V∽0.8V
600V AC
Open circuit voltage about 1.5V
Buzzer on-off
0.1Ω
About ≤60Ω
600V AC
60Ω either beep or not
Sleep
About 30min
About (5uA)
Select
Resistance/Capacitance/Diode/on-off change
√
Rel
Relative Mode
√
Hold
Data Hold
√
Hz/%
In the AC/DC/HZ/%slot(UT120A/B; PressHZ/% button turn into Hz/% to measure
√
Low Battery Indication
About <2.4V
Display & ldquo; & rdquo; Symbol
1.Auto power off (When the instrument knob and the four buttons are not responding in 30 minutes, Instruments into sleep mode.
In the sleep mode, rotate button and the instrument will auto power on
2.In the sleep mode, press SELECT button to wake up instrument,auto power off function will be cancelled.
3.After testing Hz/% and returning to DCV and ACV, the slot range is DCV-400mV, ACV-4V.
AUTO disappears in the LCD. At this time testing higher voltage, the instrument must be powered off and reset DCV, ACV for automatic range.
Leave your feedback or ask a question
Only this product is discussed here. Off topic comments will be deleted! Please follow the Commenting Rules.
The data presented in the product description are for reference only and may differ from those indicated by the manufacturer.
To carry out technical calculations and obtain the exact parameters of the goods, use the datasheets from the manufacturer's website.
If you need additional information, or you found an error in the description, or have other questions about this product, then our manager will help you: Ярослав
unknown