Digital multimeter with automatic range selection. Thermocouple for measuring temperature. Scale backlight. Mechanical protection against incorrect connection of the probes. True RMS function.
Input Impendence: >10MΩ, 60mV, 600mV range >100 MΩ
Overload protection: 250V for 60mV, 600mV range, DC 1000V or AC 750V for other ranges
600mV
0.1mV
±1.2% of rdg
6V
1mV
±0.8% of rdg
60V
10mV
±0.8% of rdg
600V
100mV
±0.8% of rdg
1000V
1V
±1.5% of rdg
ACV
(True RMS)
Range
Resolution
Accuracy
Sensitivity
input impedance : >10MΩ ;60mV, 600mV range >100 MΩ
2. Overload protect : 250V for 60mV, 600mV range, DC 1000V or AC 750V for other ranges
60mV
0.01mV
±(2.5% of rdg
40HZ-1KHZ
600mV
0.1mV
±(2.5% of rdg
40HZ-1KHZ
6V
1mV
±1.2% of rdg
40HZ-400HZ
60V
10mV
±1.2% of rdg
40HZ-400HZ
600V
100mV
±1.2% of rdg
40HZ-400HZ
750V
1V
±1.8% of rdg
40HZ-400HZ
DCA
range
Resolution
accuracy
Overload protection:
6A &20A ranges: F20A/250V fuse
Other ranges: F500mA/250V fuse
20A up to 10 seconds
600uA
0.1μA
±1.0% of rdg
6000uA
1μA
±1.0% of rdg
60mA
10μA
±1.0% of rdg
600mA
100μA
±1.0% of rdg
6A
1mA
±1.5% of rdg
20A
10mA
±1.5% of rdg
600uA
0.1μA
±1.5% of rdg
6000uA
1μA
±1.5% of rdg
60mA
10μA
±1.5% of rdg
600mA
100μA
±1.5% of rdg
6A
1mA
±2.0% of rdg
20A
10mA
±2.0% of rdg
Resistance
range
Resolution
accuracy
over-load protection: 250V effective value
600Ω
0.1Ω
±1.2% of rdg
6KΩ
1Ω
±1.2% of rdg
60KΩ
10Ω
±1.2% of rdg
600KΩ
100Ω
±1.2% of rdg
6MΩ
1KΩ
±1.5% of rdg
60MΩ
10KΩ
±2.5% of rdg
Capacitor
range
Resolution
accuracy
over-load protection: 250V effective value
9.999nF
1pF
±3.0% of rdg
99.99nF
10pF
±2.5% of rdg
999.9nF
0.1nF
±2.5% of rdg
9.999μF
1nF
±2.5% of rdg
99.99μF
10nF
±3.0% of rdg
999.9μF
0.1μF
±3.0% of rdg
9.999mF
1μF
±3.5% of rdg
99.99mF
10μF
±3.5% of rdg
Frequency Testing
range
resolution
Accuracy
Duty cycle: 1%~99% Accuracy: ±0.5
-- Overload Protection: 250V DC or rms AC, Sensitivity:Range of input voltage:1.5V~10V, If input voltage over range,need adjust
9.999Hz
0.001Hz
±0.5% of rdg
99.99Hz
0.01Hz
999.9Hz
0.1Hz
9.999kHz
1Hz
99.99kHz
10Hz
999.9kHz
100Hz
9.999MHz
1kHz
Temperature
range
resolution
Accuracy
over-load Protection: 250V DC or rms AC
-4~1832℉
1℉
±3% of rdg
-20~1000℃
1℃
±3% of rdg
Transistor Hfe Test
range
Test Range
Test Current/voltage
NPN & PNP
0-1000
Ib≈5uA/Vce≈1.8V
Diode Test
range
resolution
Function
over-load Protection: 250V effective value, forward DC current: approximate 1.5mA Reversed DC voltage: approximate 3.0V
1mV
Display: read approximate forward voltage of diode
Continuity
range
Function
over-load protection: 250V effective value
Built-in buzzer will sound if resistance is lover than50Ω
Leave your feedback or ask a question
Only this product is discussed here. Off topic comments will be deleted! Please follow the Commenting Rules.
The data presented in the product description are for reference only and may differ from those indicated by the manufacturer.
To carry out technical calculations and obtain the exact parameters of the goods, use the datasheets from the manufacturer's website.
If you need additional information, or you found an error in the description, or have other questions about this product, then our manager will help you: Ярослав
unknown